한국어  |  English  |  Português  |  Español

Auxiliary Measures Module

The auxiliary measure module performs control of equipments that are not configured in the DSP Data Management or that are not included in the measurement paths.

This module allows continuous current measurements on inputs 4-20 mA, 0-10 volt and temperature, these measurements can be configured by the operator to adjust the offset and gain entry in order to match the acquisition signal.

The temperature inputs are set to default to measure with sensors:

  • Infrared meter with output 1mv/°C.
  • 4-20mA input.
  • Inductive sensor with output 0-10V.
  • GAP calibration system for axes sensors.
  • Dual output accelerometer sensor 10mV / ° C.

 

 

 

 

 

 

 

The software DSP Data Management allows optimizing, organizing and storing the measures made with the DSP Logger MX 300.
This software delivers a wide variety of measures that can be configured previously, giving a large and organized structure.
The software has a bunch of tools which allows to produce an accurate diagnostic about eventual failures in the equipment and its work condition.

   

Specifications

Inputs
16 bits
- Two accelerometers (50 100 500mv/g, selected by software)
- Clamp meters (10 100 1000 a, software selected)
- Two displacement (0 10 V or 10 V p-p)
- Auxiliary measure (1 VRMS, AC connection)
- Optical sensor for RPM measures and external trigger.
24 bits
- Infrared sensor.
- Passive temperature sensors (pt 100) and active (0-100°c)
- Process signals (4 - 20 mA) units designation and offset control.
- DC Voltage (0 10V) units designation and offset control..
- Displacements (0 10V) units designation and offset control..
- Auxiliary DC Voltage (0-2.5V) units designation and offset control

Output
Stereo earphone. Power 100 mW at 8 Ohms.

Features
DSP Processor ADSP 2188 , 48 MHz.
Acceleration, Velocity, clamp meter and auxiliary input spectrums
Envelope Spectrum (2 filters which can be configured)
Waveform
Overall Acceleration and Velocity: 0-Peak & RMS.
Overall Displacement Peak to Peak
Natural frequency
Phase between two channels without trigger
One and two plane automatic dynamic balance.
Frequency Response: 0.2Hz 20,000Hz
Ranges: 25Hz, 100Hz, 200Hz, 500Hz 1,000Hz, 2,000Hz, 5,000Hz, 10,000Hz,15,000Hz, 20,000Hz.
Side bands in spectra: Harmonics
Zoom in spectra
Bearing fault frequencies in envelope spectra
RMS for bands x4 or x10
Windows hanning, flattop and rectangular
Graphic spectrum: linear and logarithmic
Cursor single, harmonic, harmonic+ single, peak
Trigger: external, input channel triggering
Sealing IP 65.
USB Port for PC connection
16 Mb of FLASH memory allow storing 16,000 spectra in routes
320 x 240 monochromatic pixels LCD with LED backlight. Suitable to be used with direct solar light
Operating Temperature -10 deg C to + 60 deg C
Housing material : aluminum extrusion
Battery: NiMH 7.2 V, 3,500 mAhr rechargeable. Operating time : 8 hours
Size: 7.7 in x 7.7 in x 2.05 in (195mm*195mm*52mm)
Weight: 3.97 lb (1.80Kg.)